Scientific journal NRU ITMO
Series "Refrigeration and Air Conditioning"
Registration certificate ЭЛ № ФС 77 – 55410 от 17.09.2013
зарегистрировано в Федеральной службе по надзору в сфере связи, информационных технологий и массовых коммуникаций
ISSN:2310-1148

2014 (published: 08.09.2014)

Number 2(15)

Home > Issue > Improving methods of designing cooling systems outdoor sports facilities seasonal operation

UDC 621. 59/56

Improving methods of designing cooling systems outdoor sports facilities seasonal operation

Eglit A. Yu., Kisser K.V.

Currently caloric calculation of open ice field (rink) is performed based on Encyclopedic Handbook "Refrigeration", in turn, these are number of questions raised concerning relative heat transfer coefficient, wind speed, air temperature, air humidity, and an inverse magnitude evaporation coefficient.In the given article an analyzes of the influence of climatic parameters for the Almaty city (Kazakhstan) such as wind speed, solar radiation, air humidity, air temperature, which directly affect the total heat flow is performed, an alternate design procedure of heat influxes for artificial open ice rinks with seasonal operation is offered as well as that  a thermal load calculation for refrigeration equipment is considered. The data received during research can be used for thermal calculation of open ice field by design organizations.
Read the full article 

Keywords: thermal calculation, the total heat gain, open artificial ice rink.

Editorial address:
191002, St. Petersburg, street. Lomonosova 9, office. 2132

Information 2007-2024, All rights reserved
Development by Department of Internet Solutions NRU ITMO © 2013
Яндекс.Метрика